Portrait of Svante Arrhenius

Reaction kinetics

Svante was a smart guy

The Arrhenius Term Explorer

Nikolas Milchers, Noel Marks, Goezde Ergun, Annika Kirsten, Detlef Diesing

The rate constant from 1 K to 1000 K for a chosen activation energy. The same curve, three ways: k(T), ln k versus T, and the classic Arrhenius plot.

You’re in the lab!

Edit the reference temperatures to update the rate ratio and plots.

  1. Can you double the reaction rate? Keep T1 and Ea fixed. Predict what T2 you’ll need, then test it.
  2. Estimate the activation energy. Set T1 and T2 to the temperatures you used in the lab. Adjust Ea until the predicted rate ratio is as close as possible to your measured ratio.

What changes in the Arrhenius plot in each case?

Calculating…

1 · k versus temperature
2 · ln k versus temperature
3 · Arrhenius plot: ln k versus 1/T
About the model
  • k = A exp(−Ea / RT). The temperature dependence sits in the exponential.
  • Ea runs from 1 to 250 kJ/mol. A is a relative pre-exponential factor. It scales k and shifts ln k by a constant. It does not change the rate ratio, and it does not change the slope of the Arrhenius line.
  • The window is 1 K to 1000 K. It shows how sharply k leaves the low-temperature region. The final leveling toward A enters this window only when the activation energy is small.
  • The defaults, 303 K and 353 K, stand in for a rise from about 30 °C to about 80 °C.
Reading the three plots
  • Low temperature. k stays near zero, then rises faster than a straight line. When Ea is large compared with RT, a small step up in temperature multiplies the rate by a large factor.
  • Intermediate temperature. Over a short laboratory window the rise can look nearly linear. Many teaching experiments sit here.
  • High temperature. The slope eventually falls and k levels toward A. For a large activation energy that leveling lies well above 1000 K, so this window is still the steep part of the curve. Lower Ea to bring the bend into the graph.
  • The Arrhenius plot is a straight line whenever Ea and A are constant. The slope is −Ea/R. A line fit says that one activation energy describes the data. The size of the rate change is in the first plot and in the rate ratio above.
  • On a wide screen the three graphs stay in view together. The second and third use a fixed vertical scale, so dragging Ea sweeps ln k across the window and rotates the Arrhenius line instead of stretching the axes around it. That Arrhenius frame runs from about 125 K to 1250 K. High temperature is on the right.